(5.2)

In order to carry out the sizing of this equipment, the generator-inverter relative size is defined so that the photovoltaic generator is oversized between 0.8 and 1 with respect to the inverter according to [2–4], due to the following technical reasons:Reduced system cost (smaller inverter) without significantly affecting energy efficiency.

The rated power of the generator corresponds to standard conditions, which are not common in practice.

The nominal power of the inverter is the output power; its losses must be taken into account.